Platform
Accept, Record, Guarantee.
Three layers, in the order a customer meets them. What goes into the pack, what it is doing once it is running, and what is actually left in it. We mark what earns today rather than blurring it.
Status
What ships, what is in the field, what is not built.
Shipping
IoT telemetry unit
EV and stationary. Field-test ready.
In field validation
Fleet telemetry deployment
Commercial mobility operator. First units in the field, November 2026.
In development
Chapter XA record gateway
Ingests any BMS. Indian-resident archive.
Cell lot acceptance protocol
Bench commissioning December 2026.
45 °C degradation matrix
Arrhenius, four simultaneous temperatures.
01 · What goes in
Accept
We grade the cell lot before it is built into anything. Capacity dispersion, DC internal resistance, self-discharge and an EIS fingerprint, tied to the lot and date code, with a release certificate.
- Priced as basis points of the cell invoice, not as hours
- Counterfeit and substandard LFP enters India at a 12 to 15 percent discount
- Cells rated 3,000 cycles have collapsed under 700 within 18 months
- An analytics vendor can surveil a fleet. It cannot accept a batch nobody has bought yet.
NREL BLAST-Lite, declared calibration range
“the model will likely make very poor extrapolations outside of this tested temperature range for cycling fade”NREL BLAST-Lite, lfp_gr_250AhPrismatic_2019, source comment
02 · What it is doing
Record
A gateway and an Indian-resident archive that ingests whatever BMS is already in the container, produces the 122(B)(5)(a) record at cell, module and rack level, retains it ten years, files the 48-hour incident report and runs the six-monthly checklist.
- Reads any BMS over Modbus, CAN or IEC 61850. Ours is not a precondition.
- Retrofits onto assets already commissioned with a foreign BMS inside
- Scales with the whole pipeline, not only with new Indian-BMS builds
- Your container vendor is in Ningde and has no Indian entity
03 · What is actually left
Guarantee
An annual witnessed capacity test, a measured-versus-warranted degradation opinion, and a residual-value certificate. We sign a measurement and an opinion, not a warranty.
- Measured at 45 °C, not modelled at 25 °C
- A stated error band and a reproducible protocol, or it is not a measurement
- We are not the insurer. We are the reason the insurer can price it.
- Priced against the liquidated damages it prevents, not against bench hours
Velospur Advanced Materials
Capacity Test Certificate
- Asset
- BLR-C4-011
- Chemistry
- LFP / graphite, prismatic
- Nameplate
- 1.20 MWh
- Commissioned
- 14 Mar 2026
Measured state of health
± 0.6 pp, k = 2
In shortfall
Measured against warranted
annual, since commissioning
Method
- Protocol
- Full discharge, C/3, constant current
- Ambient
- 45.0 °C, chamber controlled
- Cut-off
- 2.50 V / cell, rack mean
- Instrument
- 4-wire, calibrated 09 Aug 2026
- Repeats
- 3, spread within band
Opinion
A measurement and an opinion. Not a warranty.
Signed for the laboratory
Ed25519, key VAM-LAB-01
sha256 4f2a 91c7 0b3e dd18
Velospur Advanced Materials Private Limited
Said preciselyWe sign a measurement and an opinion, not a warranty. That is the scope every certification body works to. We are not the insurer. We are the reason the insurer can price it.
Specification
Numbers, not adjectives.
Values on unreleased hardware are design targets and are labelled as such. We will publish measured values when they are measured.
IoT telemetry unit / shipping
- Deployment
- EV and stationary, retrofit or integrated
- Per-cell voltage
- 10 s sampling, local ring buffer, opportunistic backfill
- Module current
- 1 s
- Temperature
- 15 s
- Connectivity
- Cellular, eSIM
- Data retained
- Raw per-cell series, not min/max/mean summaries
BESS BMS, 400 V and 600 V / in development
- Architecture
- String, stationary
- Target configurations
- 400 V and 600 V
- Functional safety
- Design target, to be stated on release
- Isolation monitoring
- Continuous, resolution to be stated on release
- Comms
- CAN, Modbus to PCS
- Certification path
- UL 1973 and UL 9540 transfer for the integrator
Tell us what you have in the field and what you need to prove about it.